2004 Nissan Frontier
Mileage
308,121
Service Date
5/10/2018
Services Performed
- Inspected for A/C system leaks and found A/C suction hose and A/C discharge hose are both leaking.
- Evacuated the A/C system and recovered .02 lbs R134a. Removed the A/C suction hose and replaced with new. Removed the A/C discharge hose and replaced with new. Performed automated vacuum leak test, passed. Recharged the A/C system to specification. Performed A/C system performance test, passed. A/C operates as designed.
- AIR COND HOSE – Remove and Replace – Each Additional – [DOES NOT include Air Conditioning System recover, evacuate and/or recharge.]
Zachary D. gave our service a 5 star review on 5/24/2018